117 research outputs found
A Teaching Case Study: Roxy Music Limited
Roxy Music Limited is a wholesale supplier of Compact Discs (CDs), Music Cassettes, Videos and, more recently DVDs, in the New Zealand music and entertainment market. All products are imported from Germany, the United Kingdom, the United States of America or Holland. Product arrives in boxes of 1,000 units. For the purpose of this case, we are focusing on CD sales
Cultural Differences In Learning And Implications For Distance Delivery Of Educational Programmes To Developing Nations: A Case Study In Fiji
Shanahan (2006) found that to be effective the delivery of distance learning programmes to developing nations had to overcome certain constraints, such as cultural constrictions (i.e., issues of language), tradition-based limitations (i.e., paternalistic and hierarchical structures), an inherited past (colonialism), and poor infrastructure (particularly in relation to telecommunications). It was argued that all of these obstacles needed to be managed and sufficiently overcome if distance delivery was to be of any utility. This study builds upon this research to include possible differences in learning styles across cultures that may influence the functionality of web-based distance learning programmes. Fiji was chosen as a useful case study as this country has a population that is almost evenly split between two cultures: indigenous Fijians and people of Indian ancestry who were born in Fiji. These people were submitted to the same integrated educational systems, governmental processes, economic constraints, and social norms and laws. Participants in this study completed the Lincoln VARK Learning Styles Questionnaire[1] and comparisons were made between learning styles and by ethnicity, age, computer access, and job position. Results indicated no significant difference in learning styles between cultures, but significant differences between learning styles across the total sample were evident. The results suggest learning differences need to be taken into account if maximum outcomes are to be achieved from web-based distance learning programmes. Such a finding has ramifications for educational institutions offering distance learning curriculums as the poor completion rates may partly be a function of not moderating such programmes to cater to the differences in learning styles. It is simply not a totalitarian process. [1] Copyright Version 7.0 (2006) held by Neil D. Fleming, Christchurch, New Zealand and Charles C. Bonwell, Green Mountain Falls, Colorado 80819 U.S.A 
Long-Baseline Neutrino Facility (LBNF) and Deep Underground Neutrino Experiment (DUNE) Conceptual Design Report Volume 2: The Physics Program for DUNE at LBNF
The Physics Program for the Deep Underground Neutrino Experiment (DUNE) at
the Fermilab Long-Baseline Neutrino Facility (LBNF) is described
Haematopoietic SCT in severe autoimmune diseases: updated guidelines of the European Group for Blood and Marrow Transplantation
In 1997, the first consensus guidelines for haematopoietic SCT (HSCT) in autoimmune diseases (ADs) were published, while an international coordinated clinical programme was launched. These guidelines provided broad principles for the field over the following decade and were accompanied by comprehensive data collection in the European Group for Blood and Marrow Transplantation (EBMT) AD Registry. Subsequently, retrospective analyses and prospective phase I/II studies generated evidence to support the feasibility, safety and efficacy of HSCT in several types of severe, treatment-resistant ADs, which became the basis for larger-scale phase II and III studies. In parallel, there has also been an era of immense progress in biological therapy in ADs. The aim of this document is to provide revised and updated guidelines for both the current application and future development of HSCT in ADs in relation to the benefits, risks and health economic considerations of other modern treatments. Patient safety considerations are central to guidance on patient selection and HSCT procedural aspects within appropriately experienced and Joint Accreditation Committee of International Society for Cellular Therapy and EBMT accredited centres. A need for prospective interventional and non-interventional studies, where feasible, along with systematic data reporting, in accordance with EBMT policies and procedures, is emphasized
Identification and reconstruction of low-energy electrons in the ProtoDUNE-SP detector
Measurements of electrons from interactions are crucial for the Deep
Underground Neutrino Experiment (DUNE) neutrino oscillation program, as well as
searches for physics beyond the standard model, supernova neutrino detection,
and solar neutrino measurements. This article describes the selection and
reconstruction of low-energy (Michel) electrons in the ProtoDUNE-SP detector.
ProtoDUNE-SP is one of the prototypes for the DUNE far detector, built and
operated at CERN as a charged particle test beam experiment. A sample of
low-energy electrons produced by the decay of cosmic muons is selected with a
purity of 95%. This sample is used to calibrate the low-energy electron energy
scale with two techniques. An electron energy calibration based on a cosmic ray
muon sample uses calibration constants derived from measured and simulated
cosmic ray muon events. Another calibration technique makes use of the
theoretically well-understood Michel electron energy spectrum to convert
reconstructed charge to electron energy. In addition, the effects of detector
response to low-energy electron energy scale and its resolution including
readout electronics threshold effects are quantified. Finally, the relation
between the theoretical and reconstructed low-energy electron energy spectrum
is derived and the energy resolution is characterized. The low-energy electron
selection presented here accounts for about 75% of the total electron deposited
energy. After the addition of lost energy using a Monte Carlo simulation, the
energy resolution improves from about 40% to 25% at 50~MeV. These results are
used to validate the expected capabilities of the DUNE far detector to
reconstruct low-energy electrons.Comment: 19 pages, 10 figure
The DUNE Far Detector Interim Design Report, Volume 3: Dual-Phase Module
The DUNE IDR describes the proposed physics program and technical designs of the DUNE far detector modules in preparation for the full TDR to be published in 2019. It is intended as an intermediate milestone on the path to a full TDR, justifying the technical choices that flow down from the high-level physics goals through requirements at all levels of the Project. These design choices will enable the DUNE experiment to make the ground-breaking discoveries that will help to answer fundamental physics questions. Volume 3 describes the dual-phase module's subsystems, the technical coordination required for its design, construction, installation, and integration, and its organizational structure
Impact of cross-section uncertainties on supernova neutrino spectral parameter fitting in the Deep Underground Neutrino Experiment
A primary goal of the upcoming Deep Underground Neutrino Experiment (DUNE) is
to measure the MeV neutrinos produced by a Galactic
core-collapse supernova if one should occur during the lifetime of the
experiment. The liquid-argon-based detectors planned for DUNE are expected to
be uniquely sensitive to the component of the supernova flux, enabling
a wide variety of physics and astrophysics measurements. A key requirement for
a correct interpretation of these measurements is a good understanding of the
energy-dependent total cross section for charged-current
absorption on argon. In the context of a simulated extraction of
supernova spectral parameters from a toy analysis, we investigate the
impact of modeling uncertainties on DUNE's supernova neutrino
physics sensitivity for the first time. We find that the currently large
theoretical uncertainties on must be substantially reduced
before the flux parameters can be extracted reliably: in the absence of
external constraints, a measurement of the integrated neutrino luminosity with
less than 10\% bias with DUNE requires to be known to about 5%.
The neutrino spectral shape parameters can be known to better than 10% for a
20% uncertainty on the cross-section scale, although they will be sensitive to
uncertainties on the shape of . A direct measurement of
low-energy -argon scattering would be invaluable for improving the
theoretical precision to the needed level.Comment: 25 pages, 21 figure
Deep Underground Neutrino Experiment (DUNE), Far Detector Technical Design Report, Volume III: DUNE Far Detector Technical Coordination
The preponderance of matter over antimatter in the early universe, the dynamics of the supernovae that produced the heavy elements necessary for life, and whether protons eventually decay -- these mysteries at the forefront of particle physics and astrophysics are key to understanding the early evolution of our universe, its current state, and its eventual fate. The Deep Underground Neutrino Experiment (DUNE) is an international world-class experiment dedicated to addressing these questions as it searches for leptonic charge-parity symmetry violation, stands ready to capture supernova neutrino bursts, and seeks to observe nucleon decay as a signature of a grand unified theory underlying the standard model. The DUNE far detector technical design report (TDR) describes the DUNE physics program and the technical designs of the single- and dual-phase DUNE liquid argon TPC far detector modules. Volume III of this TDR describes how the activities required to design, construct, fabricate, install, and commission the DUNE far detector modules are organized and managed. This volume details the organizational structures that will carry out and/or oversee the planned far detector activities safely, successfully, on time, and on budget. It presents overviews of the facilities, supporting infrastructure, and detectors for context, and it outlines the project-related functions and methodologies used by the DUNE technical coordination organization, focusing on the areas of integration engineering, technical reviews, quality assurance and control, and safety oversight. Because of its more advanced stage of development, functional examples presented in this volume focus primarily on the single-phase (SP) detector module
- âŠ